MG-MICA MULTIPURPOSE GRID AND ACCESSORIES
PN: 05.147.034.01 A
Page 19 of 44
Meyer Sound Laboratories Inc.
www.meyersound.com
T: +1 510 486.1166
F: +1 510 486.8356
Table 2. Load Rating if Center of Gravity falls in Zone 2
Factor of Safety
Front Flown Position Rear Flown Position
FS5
FS7
FS5
FS7
Total Suspended Weight
3,355 lbs
(1,522 kg)
2,580 lbs
(1,170 kg)
3,355 lbs
(1,522 kg)
2,580 lbs
(1,170 kg)
MICA Equivalent Cabinets
21 16 21 16
Maximum Grid Tilt
-30º to +30º -30º to +30º -30º to +20º -30º to +20º
NOTE: In order to achieve the ratings in Table 2, the following conditions need to be met:
■ The grid tilt angle cannot be greater than the angles in the table with respect to the horizontal.
Negative angles are downtilt and positive angles are uptilt angles.
■ The array is not pulled from points other than the ones on the MG-MICA grid.
■ No pull-back motor is used for tilting the array.
■ The optional MGCP-MICA center point rigging beam is not used.
■ The center of gravity of the array must be located in Zone 2 (or Zone 1). MAPP Online Pro
must be used to find out this information.
Figure 4.10. Example of a COG in Zone 2
Figure 4.11. Zone 2 Center of Gravity in the Edit Loudspeaker Systems dialog